subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Power Transistor HVAC > < Hose/Line HVAC|Testing and Inspection
Page 1
background image

Hose/Line HVAC: Service and Repair

Hose and Pipe

REMOVAL

CAUTION:

-

When disconnecting hoses, do not apply an excessive force to them. After installing, check that no torsion or excessive tension applied to
the hoses.

-

Seal the disconnected hose with a plug or vinyl tape to prevent foreign matter from entering.

1. Disconnect the ground cable from battery.
2. Using the refrigerant recovery system, discharge refrigerant.
3. Remove the bolt and detach the hoses and pipes.

INSTALLATION

CAUTION:

-

Replace the O-rings with new parts.

-

When connecting hoses, do not apply an excessive force to them. After installing, check that no torsion or excessive tension applied to the
hoses.

1. Install in the reverse order of removal.
2. Charge refrigerant.

Tightening torque: N.m (kgf.m, ft.lb)
T1: 7.5 (0.76, 5.5)
T2: 10 (1.0, 7.4)

Power Transistor HVAC > < Hose/Line HVAC|Testing and Inspection