subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Variable Induction Control Valve|Testing and Inspection|Page 2561 > < Variable Induction Control Valve|Testing and Inspection
Page 1
background image

Variable Induction Control Valve: Service and Repair

Tumble Generator Valve Assembly

REMOVAL

1. Release the fuel pressure.
2. Disconnect the ground cable from battery.

3. Open the fuel filler lid and remove the fuel filler cap.
4. Remove the intake manifold.
5. Disconnect the connector from the tumble generator valve assembly.

6. Remove the fuel injector.
7. Remove the tumble generator valve assembly from the intake manifold.

INSTALLATION

Install in the reverse order of removal.

NOTE:  Use a new gasket.

Variable Induction Control Valve|Testing and Inspection|Page 2561 > < Variable Induction Control Valve|Testing and Inspection