subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Starter Motor|Service and Repair > < Starter Motor Circuit|Page 3755
Page 4
background image

1. No.load test

With switch on, adjust the variable resistance until the voltage is 11 V, read the value of ammeter to measure starter speed. Compare these
values with the standard.

No.load test (standard):

Voltage/Current
MT model Max. 11 V/95 A
AT model Max. 11 V/90 A

Rotating speed
MT model 2,500 rpm or more
AT model 2,000 rpm or more

2. Load test

Apply the specified braking torque to starter. The condition is normal if the current draw and starter speed are within standard.

Load test (standard):

Voltage/Load
MT model 7.5 V/8.84 N.m (0.9 kgf.m, 6.5 ft.lb)
AT model 7.7 V/16.7 N.m (1.7 kgf.m, 12.3 ft.lb)

Current/Speed:
MT model 300 A/870 rpm or more
AT model 400 A/710 rpm or more

3. Lock test

With the starter stalled, or not rotating, measure the torque developed and current draw when the voltage is adjusted to standard voltage.

Lock test (standard):

Voltage/Current
MT model 4 V/680 A or less
AT model 3.5 V/960 A or less

Torque
MT model 17 N.m (1.7 kgf.m, 12.5 ft.lb) or more
AT model 31 N.m (3.2 kgf.m, 22.9 ft.lb) or more