1. ABNORMAL LOW-PRESSURE OPERATION

-

All contact points are open (OFF) since the tension of the diaphragm springs is greater than refrigerant pressure.

-

Approx. 186 kPa (1.9 kg/sq.cm, 27 psi) < P < approx. 1,471 kPa (15 kg/sq.cm, 213 psi) 

When refrigerant pressure is greater than 186 kPa (1.9 kg/sq.cm, 27 psi), diaphragm spring is inverted so that low switch is opened (OFF).

2. ABNORMAL HIGH-PRESSURE OPERATION

When refrigerant pressure is greater than 2,746 kPa (28 kg/sq.cm, 398 psi), diaphragm spring is inverted so that high switch is opened (OFF) and
low switch is closed (ON).