subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Relays and Modules - HVAC > < Refrigerant Pressure Sensor / Switch, HVAC|Specifications
Page 1
background image

Refrigerant Pressure Sensor / Switch: Testing and Inspection

Pressure Switch (Dual Switch)

NOTE:  Pressure switch is attached to receiver dryer. It has two built-in switches.

1. Remove cap from high-pressure line service valve, and connect gauge manifold to service valve.
2. Disconnect pressure switch harness connector, and check pressure switch for proper ON-OFF operation. Use a circuit tester.