Impreza RS Coupe AWD F4-2.5L SOHC (1999)
Positive Crankcase Ventilation Valve: Service and Repair
FICD Device - 1, PCV Valve - 2
REMOVAL
1.
Remove the hose from the valve.
2.
Remove the valve in the counterclockwise direction.
INSTALLATION
1.
Reinstall the valve and tighten to 20 - 35 Nm (14 - 19 ft lb).
2.
Reconnect the hose.