subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Front Oxygen (A/F) Sensor|Page 315 > < Front Oxygen (A/F) Sensor|Page 312
Page 1
background image

Oxygen Sensor: Service and Repair
Front Oxygen (A/F) Sensor

Removal

1. Disconnect battery ground cable.

2. Disconnect connector from front oxygen sensor.
3. Lift-up the vehicle.
4. Apply SUBARU CRC or its equivalent to threaded portion of front oxygen (A/F) sensor, and leave it for one minute or more. 

SUBARU CRC (Part No.004301003)

5. Remove front oxygen (A/F) sensor.

CAUTION:  When removing, do not force front oxygen (A/F) sensor in an unnatural way especially when exhaust pipe is cold, otherwise it will
damage exhaust pipe.

Installation

Front Oxygen (A/F) Sensor|Page 315 > < Front Oxygen (A/F) Sensor|Page 312