(4) Remove the ignition coil.
(5) Place a suitable container under the vehicle.
(6) Disconnect the PCV hose from the rocker cover (LH).
(7) Remove the bolts, then remove the rocker cover (LH).

11) Turn the crank pulley clockwise until the round mark and arrow mark on the camshaft sprocket are set to position shown in the figure.

NOTE:  Turn the crankshaft using socket wrench.

12) Measure the #1 cylinder intake valve and #3 cylinder exhaust valve clearance by using thickness gauge (A).

NOTE:
^

Insert a thickness gauge in a direction as horizontal as possible with respect to the valve lifter.

^

Measure the exhaust valve clearances while lifting-up the vehicle.

Valve clearance:
Standard:
Intake 0.20 ± 0.02 mm (0.0079 ± 0.0008 in)
Exhaust 0.35 ± 0.02 mm (0.0138 ± 0.0008 in)
^

If the measured value is not within specification, take notes of the value in order to adjust the valve clearance later on.

13) If necessary, adjust the valve clearance.
14) Further turn the crank pulley clockwise. Using the same procedures described previously, then measure valve clearances again.

(1) Set the round mark and arrow mark on cam sprocket to the position shown in the figure, and measure the #2 cylinder exhaust valve and #3

cylinder intake valve clearances.

(2) Set the round mark and arrow mark on cam sprocket to the position shown in the figure, and measure the #2 cylinder intake valve and #4

cylinder exhaust valve clearances.

Valve Clearance|Specifications|Page 1799 > < Valve Clearance|Specifications|Page 1797