Page 4
background image

15. When the gauge needle indicates approximately 200 kPa (1,500 mmHg, 59.1 inHg), close all valves.
16. Using a leak tester, check for refrigerant leaks in the system.
17. After checking that there is no refrigerant leaks, fill with refrigerant up to the specified amount.
18. If the HFC-134a supply container becomes empty, close all valves, and close the can tap valve to replace the empty container. After replacing with

a new HFC-134a supply container, perform air purge, and resume the filling operation.

19. If the refrigerant filling efficiency drops, close all valves.
20. Check that both the low pressure and high pressure valves are closed. Start the engine with the A/C switch OFF.
21. To prevent damage to the compressor, push the A/C switch ON-OFF quickly a few times.
22. Set up the vehicle to the following status:

CAUTION:  When filling with the engine running, do not open the high pressure side valve. Always fill from the low pressure side valve.

-

A/C switch ON

-

Engine running at 1,500 rpm

-

Blower speed setting to "HI"

-

Temperature setting to "MAX COOL"

-

Air inlet setting to "RECIRC"

-

Window open

23. Open the low pressure side valve and fill with refrigerant up to the specified amount.
24. After filling with refrigerant, close all valves and disconnect the hose from the service port.
25. Attach the cap of the service port.

Refrigerant Charging Procedure|Page 758 > < Refrigerant Charging Procedure|Page 756