subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 5026 > < Initial Inspection and Diagnostic Overview|Page 5024
Page 5
background image

NO:

Replace side airbag harness. 

5W5: SIDE AIRBAG HARNESS SHORTED TO GROUND CIRCUIT INSPECTION

Measure resistance between test harness I or I2 connector (3I) terminal and chassis ground.

CHECK: Is the resistance more than 1 M ohms?

YES:

Go to step 5W6.

NO:

Replace side airbag harness. 

5W6: SIDE AIRBAG HARNESS SHORTED TO GROUND CIRCUIT INSPECTION

Measure resistance between test harness I or I2 connector (3I) terminal and chassis ground.

CHECK: Is the resistance more than 1 M ohms?

YES:

Replace airbag control module. 

NO:

Replace side airbag harness.

65 - ELR W/ Pretensioner (RH) Circuit Is Short/Power Supply

DIAGNOSIS:  ELR with pretensioner (RH) circuit is shorted to power supply.

CAUTION:  Before performing diagnostics on airbag system, turn ignition switch "OFF", disconnect battery ground cable and then wait at least 20
seconds
.

5X1: ELR WITH PRETENSIONER INSPECTION

1. Disconnect connector (AB26) from ELR with pretensioner RH side, and connect (AB26) to test harness F connector (1F).
2. Connect airbag resistor to test harness F connector (3F).
3. Connect battery ground cable and then turn ignition switch to ON (engine off). Observe airbag warning light.

CHECK: Does the airbag warning light come on for about 7 seconds, then go out and stay out?

YES:

Replace ELR with pretensioner RH side.

Initial Inspection and Diagnostic Overview|Page 5026 > < Initial Inspection and Diagnostic Overview|Page 5024