Legacy Brighton Wagon AWD F4-2.5L SOHC (2000)
NO:
Go to step 5X2.
5X2: SIDE AIRBAG HARNESS SHORTED TO POWER SUPPLY CIRCUIT INSPECTION
1. Turn ignition switch OFF, disconnect battery ground cable and then wait at least 20 seconds.
2. Disconnect side airbag connector RH side (AB24) and (AB25). (Side airbag equipped vehicle)
3. Disconnect connector (AB18) from airbag control module, and connect (AB18) to test harness I or I2 connector (1I).
4. Connect battery ground cable and then turn ignition switch ON (engine off).
5. Measure voltage between test harness I or I2 connector (3I) terminal and chassis ground.
CHECK: Is the voltage less than 1 V?
YES:
Go to step 5X3.
NO:
Replace side airbag harness.
5X3: SIDE AIRBAG HARNESS SHORTED TO POWER SUPPLY CIRCUIT INSPECTION
Measure voltage between test harness I or I2 connector (3I) terminal and chassis ground.
CHECK: Is the voltage less than 1 V?
YES:
Replace airbag control module.
NO:
Replace side airbag harness.
66 - ELR W/ Pretensioner (LH) Circuit Is Shorted/Power Supply
DIAGNOSIS: ELR with pretensioner (LH) circuit is shorted to power supply.
CAUTION: Before performing diagnostics on airbag system, turn ignition switch "OFF", disconnect battery ground cable and then wait at least 20
seconds.
5Y1: ELR WITH PRETENSIONER INSPECTION
1. Disconnect connector (AB21) from ELR with pretensioner LH side, and connect (AB21) to test harness F connector (1F).
2. Connect airbag resistor to test harness F connector (3F).
3. Connect battery ground cable and then turn ignition switch to ON (engine off). Observe airbag warning light.