Legacy Brighton Wagon AWD F4-2.5L SOHC (2000)
Base Pattern To Power Pattern
Depending on throttle opening and vehicle speed, 16 areas as shown in the figure are set. Accelerator depression speed for pattern change over is set
for each area.
When the accelerator depression speed exceeds this set value, the pattern changes from base to power.
Power Pattern To Base Pattern
The power pattern is shifted to the base pattern, depending on car speed. Shifting to the base pattern is determined by the throttle position as shown in
Figure below. Time lag in shifting is also determined by car speed. The maximum time lag is 3 seconds.