subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Intake Door Motor|Page 4763 > < Air Door Actuator / Motor, HVAC|Locations|Page 4760
Page 1
background image

Air Door Actuator / Motor: Testing and Inspection
Intake Door Motor

Intake Door Motor

1. When approx. 12 V is applied to the intake door motor terminals, intake door motor operates as follows:

2. Connect harness to intake door motor.
3. Turn ignition switch to "ACC" and RECIRC switch to "ON" then, set to "RECIRC".

NOTE:  Ensure that intake door motor is set in the "RECIRC" mode.

4. Install intake door motor on intake unit.
5. Secure rod holder to link, and install link to intake unit.
6. Manually set rod in the "RECIRC" mode, and secure to rod holder.
7. Operate mode selector switch to ensure that system changes from intake air to "RECIRC" and from "RECIRC" to intake air in full-stroke range.

Intake Door Motor|Page 4763 > < Air Door Actuator / Motor, HVAC|Locations|Page 4760