1. Rotate bearing by hand; no binding should exist.
2. Rotate bearing rapidly; no abnormal noise should be heard.

6. MAGNETIC SWITCH

CAUTION:
-

The following magnetic switch tests should be performed with specified voltage applied.

-

Each test should be conducted within 3 to 5 seconds. Power to be furnished should be one-half the rated voltage.

1. Pull-in test

Connect two battery negative leads onto magnetic switch body and terminal C respectively. Then connect battery positive lead onto terminal
50. Pinion should extend when lead connections are made.

2. Holding-in test

Disconnect lead from terminal C with pinion extended. Pinion should be held in the extended position.

3. Return test