subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Hydraulic Unit For ABS System|Page 4094 > < Hydraulic Unit For ABS System|Page 4092
Page 8
background image

2) TCS sequence control can be started by diagnosis connector or select monitor.

Operational Guidelines Of The TCS Sequence Control With Diagnoses Connector 

1) Connect diagnosis terminals to terminal No.4 of the diagnosis connector beside driver seat heater unit.
2) Ignition switch is turned to ON.
3) Make sure only the start code (code 11) is shown in normal condition.

NOTE:  When trouble codes are stored in memory, repair the faulty parts.

4) Set the speed of all wheels at 10 km/h (6 MPH) or less.
5) Turn ignition switch OFF.
6) Start engine, and within 0.5 seconds after the ABS warning light and TCS warning light go out, press 105 OFF switch. Within 1.0 second

thereafter, release and press the switch again. Then, keep the switch pressed.

NOTE: 
-

When the TCS sequence control is set to on, the brake pedal must not be depressed.

-

Engine must operate.

-

When TCS OFF switch is not depressed within 0.5 seconds after ABS and TCS warning lights turn off, the trouble code mode comes on.

7) After completion of TCS sequence control, turn ignition switch OFF.

Operational Guidelines Of The TCS Sequence Control With Select Monitor 

1) Connect select monitor to data link connector beside driver's seat heater unit.
2) Engine starts.
3) Put select monitor to TCS mode.
4) Put select monitor to FBI mode. Make sure code 11 is indicated.

NOTE; When trouble codes are stored in memory, repair the faulty parts.

5) Press FD2 ENT key.

6) When the message shown in the figure is displayed, press ENT key.
7) Checked portions will be displayed on select monitor.

Hydraulic Unit For ABS System|Page 4094 > < Hydraulic Unit For ABS System|Page 4092