subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

EGR Control Solenoid|Locations|Page 2422 > < EGR Control Solenoid|Locations|Page 2420
Page 2
background image

Voltage Test

1.

Turn ignition switch "ON".

2.

Measure voltage between solenoid connector and ground as follows:
Connector & terminal:

Voltage:

(E16)2-Ground

10 VDC minimum  

EGR Control Solenoid|Locations|Page 2422 > < EGR Control Solenoid|Locations|Page 2420