Oxygen Sensor: Service and Repair
Rear Oxygen Sensor

REMOVAL 

1. Disconnect battery ground cable.

2. Disconnect connector from rear oxygen sensor.
3. Lift-up the vehicle.
4. Apply SUBARU CRC or its equivalent to threaded portion of rear oxygen sensor, and leave it for one minute or more.

SUBARU CRC (Part No.004301003) 

5. Remove rear oxygen sensor.

CAUTION:  When removing, do not force rear oxygen sensor in an unnatural way especially when exhaust pipe is cold, otherwise it will
damage exhaust pipe.
 

INSTALLATION 

Front Oxygen (A/F) Sensor|Page 2309 > < Front Oxygen (A/F) Sensor|Page 2307