subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Starter Motor|Inspection|Page 4439 > < Starter Motor|Inspection|Page 4437
Page 1
background image

Starter Motor: Testing and Inspection
Test

1. MAGNETIC SWITCH

CAUTION:
-

The following magnetic switch tests should be performed with specified voltage applied.

-

Each test should be conducted within 3 to 5 seconds. Power to be furnished should be one- half the rated voltage.

1. Pull-in test

Connect two battery negative leads onto magnetic switch body and terminal C respectively. Then connect battery positive lead onto terminal
50. Pinion should extend when lead connections are made.

2. Holding-in test

Disconnect lead from terminal C with pinion extended. Pinion should be held in the extended position.

3. Return test

Connect two battery negative leads onto terminal 50 and onto switch body respectively. Then connect battery positive lead onto terminal C.
Next, disconnect lead from terminal 50. Pinion should return immediately.

2. PERFORMANCE TEST

The starter is required to produce a large torque and high rotating speed, but these starter characteristics vary with the capacity of the battery. It is
therefore important to use a battery with the specified capacity whenever testing the starter.
The starter should be checked for the following three items:
-

No-load test
Measure the maximum rotating speed and current under a no-load state.

-

Load test
Measure the magnitude of current needed to generate the specified torque and rotating speed.

-

Stall test
Measure the torque and current when the armature is locked.

Starter Motor|Inspection|Page 4439 > < Starter Motor|Inspection|Page 4437