subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Refrigerant Pressure Sensor / Switch, HVAC|General|Page 5038 > < Refrigerant Pressure Sensor / Switch, HVAC|General|Page 5036
Page 1
background image

Refrigerant Pressure Sensor / Switch: Description and Operation
During Abnormal Low-Pressure Operation

If the refrigerant pressure falls, the pressure on the seal film is lost, and the force exerted from the stopper, guide head, high pressure disc and high
pressure internal lid to the low pressure disc decreases, and the low pressure disc rotates back, pressing the guide pin down and causing the moving
contact to be OFF.

Refrigerant Pressure Sensor / Switch, HVAC|General|Page 5038 > < Refrigerant Pressure Sensor / Switch, HVAC|General|Page 5036