Refueling Vapor Recovery System: Description and Operation
Operation

-

While driving:
Since the back side of the diaphragm in the pressure control solenoid valve is open to the atmosphere, the diaphragm is held pressed by the
atmospheric pressure in the position where only the external air is introduced into the canister. When the evaporation gas pressure acting on the
other side of the diaphragm increases and overcomes the atmospheric pressure, it pushes the diaphragm and opens a port through which the
evaporation gas makes its way to the canister.