CAUTION:
-
Pull the connector to ensure it is connected securely.
-
Ensure the two retainer pawls are engaged in their mating positions in the connector.
-
Be sure to inspect hoses and their connections for any leakage of fuel.
2. Connect fuel delivery hose to pipe with an over-lap of 20 to 25 mm (0.79 to 0.98 in).
Type A: When fitting length is specified.
Type B: When fitting length is not specified.
l: 2.5 ± 1.5 mm (0.098 ± 0.059 in)
L: 22.5 ± 2.5 mm (0.888 ± 0.098 in)
3. Connect evaporation hose to pipe by approx. 15 mm (0.59 in) from hose end.
L = 17.5 ± 2.5 mm (0.689 ± 0.098 in)