1. No-load test

Run single starter under no-load state, and measure its rotating speed, voltage, and current, using the specified battery. Measured values must
meet the following standards:

No-load test (Standard):
Voltage/Current
11 V/90 A, or more Rotating speed
TN128000-8311: 3,000 rpm, or more
TN128000-8321: 3,350 rpm, or more

2. Load test (For reference)

Perform this test to check maximum output of starter. Use test bench which is able to apply load (brake) to starter. Measure torque value and
rotating speed under the specified voltage and current conditions while controlling braking force applied to starter.

CAUTION:  Change engagement position of overrunning clutch and make sure it is not slipping.

Load test (Standard):
TN128000-8311 

Voltage/Load

8 V/9.8 N.m (1.0 kg.m, 7.2 ft.lb) 

Current/Speed

280 A max./900 rpm mm.

TN128000-8321 

Voltage/Load

8 V/13.7 N.m (1.4 kg.m, 10.1 ft.lb) 

Current/Speed

370 A, or less/880 rpm, or more

3. Stall test

Starter Motor|Inspection|Page 4432 > < Starter Motor|Inspection|Page 4430