Loyale Sedan (4 Door) 4WD F4-1781cc 1.8L SOHC Turbo (1990)
Canister Purge Control Valve: Testing and Inspection
Auxiliary Purge Control Valve
Auxiliary Purge Control Valve
1.
Confirm that air does not pass between fittings.
2.
Apply 42 kPa (13 in Hg) pressure to fitting A. Air should pass between fittings B and C.
Replace the valve if it fails the above tests.