Page 4
background image

CAUTION:  Do not open the low-pressure valve.

CAUTION:  Never run the engine while charging from the high-pressure side.

16. Close the high-pressure valve when the low-pressure gauge reaches 98 kPa (1 kg/sq.cm, 14 psi). Using a leak tester, check the system for leaks.

If any leakage is found after the refrigerant recovery is completed, repair the applicable area.

17. After confirming that there are no leaks with the leak test, charge the required amount of refrigerant.

CAUTION:  Never run the engine while charging from the high-pressure side.

18. Close the high-pressure valve when;

-

the readings of low-/high-pressure gauges become almost equal, after the charging speed is reduced,

-

the HFC-134a source becomes empty, or the system is full with the gas.

19. If the HFC-134a source is empty, close the high-pressure valve, close the valve on the can tap, and replace the HFC-134a source with a new part to

restart the operation.

20. Confirm that both the low-/high-pressure valves can be closed. Start the engine with the A/C switch OFF.

Refrigerant Charging Procedure|Page 5001 > < Refrigerant Charging Procedure|Page 4999