subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 4279 > < Diagram Information and Instructions|Page 4277
Page 2
background image

When contacting the two leads in reverse, there should be no continuity.

3. The symbol "0-0" indicates that continuity exists between two points or terminals. For example, when a switch position is at "3", continuity

exists among terminals 1, 3 and 6, as shown in the table.

3. HOW TO DETERMINE AN OPEN CIRCUIT

1. WITH VOLTMETER:

An open circuit is determined by measuring the voltage between respective connectors and ground using a voltmeter, starting with the
connector closest to the power supply. The power supply must be turned ON so that current flows in the circuit. If voltage is not present
between a particular connector and ground, the circuit between that connector and the previous connector is open.

2. WITH OHMMETER:

Disconnect all connectors affected, and check continuity in the wiring between adjacent connectors. When the ohmmeter indicates infinite , the
wiring is open.

4. HOW TO DETERMINE A SHORT CIRCUIT

1. WITH TEST LIGHT:

Diagram Information and Instructions|Page 4279 > < Diagram Information and Instructions|Page 4277