subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Ignition System > < Variable Induction Control Valve|Locations
Page 1
background image

Variable Induction Control Valve: Service and Repair

Induction Valve

REMOVAL

1. Disconnect battery ground cable.
2. Remove intake manifold.

3. Remove induction valve from intake manifold.

INSTALLATION

Install in the reverse order of removal.

NOTE:  Always use a new gasket.

Tightening Torque:  19 Nm (1.9 kgf-m, 14 ft-lb)

Ignition System > < Variable Induction Control Valve|Locations