Oxygen Sensor: Service and Repair
Rear Oxygen Sensor

REMOVAL

1. Disconnect battery ground cable.

2. Disconnect connector from rear oxygen sensor.
3. Lift-up the vehicle.
4. Apply SUBARU CRC or its equivalent to threaded portion of rear oxygen sensor, and leave it for one minute or more.

SUBARU CRC (Part No.004301003)

5. Remove rear oxygen sensor.

CAUTION:  When removing, do not force rear oxygen sensor in an unnatural way especially when exhaust pipe is cold, otherwise it will damage
exhaust pipe.

INSTALLATION

1. Before installing rear oxygen sensor, apply anti- seize compound only to threaded portion of rear oxygen sensor to make the next removal easier.

CAUTION:  Never apply anti-seize compound to protector of rear oxygen sensor. 

Anti-seize compound:  SS-30 by JET LUBE

2. Install rear oxygen sensor.

Front Oxygen (A/F) Sensor|Page 570 > < Front Oxygen (A/F) Sensor|Page 568