When an electric current in the R solenoid valve cuts oft, the fluid entering the plunger piston pressure chamber on the right side is
compressed. Then, from an equalized position, the plunger piston moves to the right side reducing the capacity of the pressure chamber on the
left side (compressed). Thus, the pressure in the RL wheel cylinder increases. Further movement of the plunger piston opens the plunger piston
port, and the fluid pressure of the master cylinder is directly applied (at this time, the brake pedal feels as if it is being pulled in).