4) Pressure "INCREASE" Action With ABS In Operation (Explained with one wheel's control as an example) 

Since no current is supplied to the inlet and outlet solenoid valves1 no solenoid valve attracting force is generated. So the valves remain
stationary.
Accordingly, the inlet port of the inlet solenoid valve is in an opened state, whereas the outlet port of the outlet solenoid valve is in a closed
state. So the fluid pressure of the master cylinder is transmitted to the wheel cylinder to increase the brake force in the wheel cylinder.
During ABS operation, the pump motor continues to operate.