Receiver Dryer: Description and Operation
Receiver Drier

1. MECHANISM 

The amount of refrigerant circulating varies with the heat load changes. The receiver drier supplies the amount of refrigerant necessary for the
cycle according to such changes.
1) It removes bubbles from the condensed refrigerant so that only liquid refrigerant may be delivered to the expansion valve. (If bubbles are

present, the refrigerant passing through the expansion valve varies in quantity, temperature, and pressure, resulting in insufficient cooling.)

2) It removes moisture from the refrigerant.
3) It removes foreign substance from the refrigerant.
4) It permits a visual observation of the amount of refrigerant through the sight glass.
The receiver-drier consists of a strainer to remove foreign substance, desiccant to absorb moisture from refrigerant, a sight glass to check the
amount of refrigerant.