subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 3742 > < Diagram Information and Instructions|Page 3740
Page 1
background image

Brake Warning Indicator: Diagnostic Aids

Basic Procedures

BASIC PROCEDURES

1. GENERAL DESCRIPTION

The most important purpose of diagnostics is to determine which part is malfunctioning quickly, to save time and labor.

2. IDENTIFICATION OF TROUBLE SYMPTOM

Determine what the problem is based on the symptom.

3. PROBABLE CAUSE OF TROUBLE

Look at the wiring diagram and check system s circuit. Then check the switch, relay, fuse, ground, etc.

4. LOCATION AND REPAIR OF TROUBLE

1. Using the diagnostics, narrow down the causes.
2. If necessary, use a voltmeter, ohmmeter, etc.
3. Before replacing certain component parts (switch, relay, etc.), check the power supply, ground, for open wiring harness, poor connectors, etc.

If no problems are encountered, check the component parts.

5. CHECK SYSTEM OPERATION

After repairing, ensure that the system operates properly.

Basic Inspection

BASIC INSPECTION

1. VOLTAGE MEASUREMENT

1. Using a voltmeter, connect the negative lead to a good ground point or negative battery terminal and the positive lead to the connector or

component terminal.

2. Contact the positive lead of the voltmeter on connector (A). The voltmeter will indicate a voltage.
3. Shift the positive lead to connector (B). The voltmeter will indicate no voltage.
4. With the test set-up held as it is, turn the switch ON. The voltmeter will indicate a voltage and, at the same time, the light will come on.
5. The circuit is in good order. If a problem such as a light failing to illuminate occurs, use the procedures outlined above to track down

malfunction.

2. CIRCUIT CONTINUITY CHECKS

1. Disconnect the battery terminal or connector so there is no voltage between check points. Contact the two leads of an ohmmeter to each of the

check points. If the circuit has diodes, reverse the two leads and check again.

2. Use an ohmmeter to check for the diode continuity. When contacting the negative lead to diode positive side and positive lead to negative side,

there should be continuity. When contacting the two leads in reverse, there should be no continuity.

Diagram Information and Instructions|Page 3742 > < Diagram Information and Instructions|Page 3740