subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Inhibitor Switch|Page 4045 > < Inhibitor Switch|Page 4043
Page 4
background image

1. Connect the inhibitor switch harness connector to inhibitor switch.

2. Install the inhibitor switch to transmission case.
3. Move the range select lever to neutral position.

4. Using the ST, tighten the bolts of inhibitor switch.

ST 499267300 STOPPER PIN
Tightening torque: 3.5 Nm (0.36 kgf-m, 2.6 ft. lbs.) 

5. Install the select cable to range select lever. 

6. Install the plate assembly to transmission.

Tightening torque: T: 25 Nm (2.5 kgf-m, 18 ft. lbs.) 