Fuel Pump Control Unit: Testing and Inspection

Fuel Pump Connector

1. Start and warm engine to operating temperature.

2. Fold down the rear seat back, and turn up the floor mat.
3. Remove access hole lid.
4. Disconnect fuel pump connector (R23).
5. Measure voltage between connector (R23) and body the engine is running.
6. Gradually raise engine speed and confirm the  voltage lowers.
7. If the voltage did not lower, check the following:

Fig. 4 Fuel Pump Modulator And Resistor

a. Measure voltage between ECM and body.

SPECIFIED VOLTAGE:  (B61) No. 14 - Body/5V, min. 

b. Remove fuel pump modulator and measure resistance of harness connector between modulator and fuel pump.

SPECIFIED RESISTANCE:
(R33) No. 1 - (R23) No 4/0 ohms
(R33) No. 1 - (R23) No 3/0 ohms
 

c. Measure resistance between harness connector between modulator and resistor.

SPECIFIED RESISTANCE:  (R33) No. 1 - (R34) No 2/0 ohms