Inspection
Plunger
Inspect plunger for wear. Replace if necessary.
Magnetic Switch
Magnetic Switch
Push in plunger and release it. The plunger should return quickly to its original position. Replace if necessary.
Pull-in Coil Open Circuit Test
Pull-in coil open circuit test
Check for continuity across magnetic switch 'S' terminal (1) and 'M' terminal (2). If no continuity, coil is open and should be replaced.