suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Power and Ground Distribution > < Symptom Related Diagnostic Procedures|Page 3516
Page 4
background image

Hold-in Test

While connected as the figure with plunger out, disconnect negative lead from terminal "M".
Check that plunger and pinion remain out.
If plunger and pinion return inward, replace the magnetic switch.

Plunger and Pinion Return Test

Disconnect negative lead from starting motor body.
Check that plunger and pinion return inward.
If plunger and pinion don't return, replace the magnetic switch.

No-load Performance Test

Connect battery and ammeter to starter as shown.
Check that starter rotates smoothly and steadily with pinion moving out. Check that ammeter indicates specified current.

Specified current (No-load performance test): 90 A MAX. at 11 V

Power and Ground Distribution > < Symptom Related Diagnostic Procedures|Page 3516