suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Power Mirror Control Module > < Keyless Entry System - Inoperative Using Transmitter|Page 37
Page 1
background image

Keyless Entry Relay: Testing and Inspection

Keyless Answer Back Relay Inspection

1. Check that there is no continuity between terminal "C" and "D". If there is continuity, replace relay.
2. Connect battery positive (+) terminal to terminal "B" of relay.

Connect battery negative (-) terminal to terminal "A" of relay.
Check continuity between terminal "C" and "D".
If there is no continuity when relay is connected to the battery, replace relay.

Power Mirror Control Module > < Keyless Entry System - Inoperative Using Transmitter|Page 37