Aerio AWD L4-2.0L (2003)
Shift Solenoid: Testing and Inspection
Solenoid Valves (Shift Solenoid Valves and TCC Solenoid Valve) Inspection
Resistance Check
Shift solenoid valve-A (No.1), -B (No.2) and TCC solenoid valve
Shift solenoid valves and TCC solenoid valve resistance
Standard: 11 - 15 ohms at 20°C (68°F)
Operation Check
Shift solenoid valve-A (blow) and -B (No.2)
^
Check that solenoid valve (1) actuate with click sound when battery voltage is conducted.
^
Apply oiler (2) to solenoid valve (1) and give compression by hands and then check to be sure that transaxle fluid from oiler does not come out of
holes in solenoid valve when battery voltage is not conducted.
^
Under the same conditions, conduct battery voltage and then make sure that fluid comes out with vigor. If check result is not as described, replace
shift solenoid valve.
TCC solenoid valve