Equator 2WD V6-4.0L (2009)
Catalytic Converter: Service and Repair
Exhaust Manifold and Three Way Catalyst: Removal and Installation
Exhaust Manifold and Three Way Catalyst: Removal and Installation [VQ4ODE]
REMOVAL (LH)
WARNING:
Perform the work when the exhaust and cooling system have cooled sufficiently.
1) Remove air cleaner case and air duct and resonator assembly.
2) Remove the air dam using power tool.
3) Remove engine undercover using power tool.
4) Disconnect harness connector and remove LH and RH heated oxygen sensor 2 using Tool.
Tool number: KV10114400 (J-38365)
CAUTION:
^
Be careful not to damage heated oxygen sensor 2.
^
Discard any heated oxygen sensor 2 which has been dropped from a height of more than 0.5 m (19.70 in) onto a hard surface such
as a concrete floor; replace with a new sensor.
5) Remove center exhaust tube, main muffler and left front exhaust tube.
6) Remove exhaust manifold cover (LH).
7) Disconnect harness connector and remove air fuel ratio sensor 1 (LH) using Tool (A).