suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Checking Procedure|Page 4095 > < Checking Procedure|Page 4093
Page 1
background image

Refrigerant: Testing and Inspection
Checking System For Leaks Using the Fluorescent Dye Leak Detector

Checking System for Leaks Using the Fluorescent Dye Leak Detector

1. Check the A/C system for leaks using the fluorescent dye leak detector and safety goggles (J-42220) in a low sunlight area (area without windows

preferable). Illuminate all components, fittings and lines. The dye will appear as a bright green/yellow area at the point of leakage. Fluorescent dye
observed at the evaporator drain opening indicates an evaporator core assembly leak (tubes, core or expansion valve).

2. If the suspected area is difficult to see, use an adjustable mirror or wipe the area with a clean shop rag or cloth, then inspect the shop rag or cloth

with the fluorescent dye leak detector (J-42220) for dye residue.

3. After the leak is repaired, remove any residual dye using refrigerant dye cleaner (J-43872) to prevent future misdiagnosis.
4. Perform a system performance check and then verify the leak repair using a electronic refrigerant leak detector (J-41995).

NOTE:
-

Other gases in the work area or substances on the A/C components, for example, anti-freeze, windshield washer fluid, solvents and oils, may
falsely trigger the leak detector. Make sure the surfaces to be checked are clean.

-

Clean with a dry cloth or blow off with shop air.

-

Do not allow the sensor tip of the electronic refrigerant leak detector (J-41995) to contact with any substance. This can also cause false
readings and may damage the detector.

Checking Procedure|Page 4095 > < Checking Procedure|Page 4093