Equator 2WD V6-4.0L (2009)
a) If small metal debris less than 1mm (0.040 in) in size or metal powder is found in the coffee filter, this is normal. If normal debris is found, the
A/T fluid cooler/radiator can be re-used and the procedure is ended.
b) If one or more pieces of debris are found that are over 1mm (0.040 in) in size and/or peeled clutch facing material is found in the coffee filter,
the fluid cooler is not serviceable. The A/T fluid cooler/radiator must be replaced and the inspection procedure is ended.