Hydraulic Control Assembly - Antilock Brakes: Testing and Inspection

OPERATION CHECK 

1. Check that basic brake system other than Antilock Brake System (ABS) is in good condition.

2. Check that battery voltage is 11V or higher.
3. With "ABS" warning lamp, check that no abnormality is detected in ABS. 
4. Lift up vehicle.
5. Set transmission to neutral and release parking brake.
6. Turn each wheel gradually by hand to check if brake dragging occurs. If it does, correct.

7. With diagnostic switch terminal of DIAGNOSTIC-2 connector connected to ground by using service wire, turn ignition switch ON and check if

"ABS" warning lamp indicates DTC 12.

8. Turn ignition switch "OFF".

9. Perform following checks with help of another person. Brake pedal should be depressed and then ignition switch turned ON by one person and

wheel should be turned by another person's hand. At this time, check that:
^

Operation sound of solenoid is heard and wheel turns only about 0.5 seconds (Brake force is Repressurized).

Hydraulic Control Assembly - Antilock Brakes|Description and Operation|Page 2581 > < Hydraulic Control Assembly - Antilock Brakes|Description and Operation