7. If valve lash is out of specification, adjust it to specification by turning adjusting screw after loosening lock nut. After adjustment, tighten lock nut

to specified torque while holding adjusting screw stationary, and then make sure again that valve lash is within specification.

Valve clearance specification (intake and exhaust):

When cold (Coolant temperature is 15 - 25°C or 59 - 77°F): 0.13 - 0.17 mm (0.005 - 0.007 inch) 
When hot (Coolant temperature is 60 - 68°C or 140 - 154°F): 0.17 - 0.21 mm (0.007 - 0.008 inch) 

Special Tool, or equivalent (A): 09917-18210

Tightening Torque (a): 12 Nm (108 inch lbs.) 

8. After checking and adjusting valve lashes at valves (1), (2), (5) and (7), (or (3), (4), (6) and (8)) rotate crankshaft exactly one full turn (360°) and

check the same at valves (3), (4), (6) and (8) (or (1), (2), (5) and (7)). Adjust them as necessary. 

9. After checking and adjusting all valves, reverse removal Procedure for installation.

Computers and Control Systems > < Valve Clearance|Specifications|Page 1300