suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Condenser HVAC|Description and Operation|Page 3323 > < Condenser HVAC|Description and Operation|Page 3321
Page 1
background image

Condenser HVAC: Service and Repair

CONDENSER 

REMOVAL 

1. Disconnect negative (-) cable at battery.
2. Recover refrigerant by using recovery and recycling equipment. Be sure to follow the instruction manual for the equipment. The amount of

compressor oil removed must be measured and the same amount added to the system.

3. Remove front bumper.

4. Disconnect compressor delivery hose from condenser inlet fittings.

NOTE:  As soon as above hose and pipe are disconnected, cap opened fittings so that moisture and dust do not enter condenser.

5. Remove horn.

6. Remove hood latch and hood lock member.

7. Disconnect coupler from dual pressure switch.
8. Remove receiver outlet pipe.

Condenser HVAC|Description and Operation|Page 3323 > < Condenser HVAC|Description and Operation|Page 3321