Coolant: Service and Repair
Engine Coolant Change

Engine Coolant Change

WARNING:  To help avoid danger of being burned, do not remove radiator cap while engine and radiator are still hot. Scalding fluid and
steam can be blown out under pressure if cap is taken off too soon.

1. Remove radiator cap when engine is cool.
2. Loosen radiator drain plug to drain coolant.
3. Remove reservoir tank and drain.
4. Tighten drain plug securely. Also install reservoir tank.
5. Fill radiator with specified amount of coolant, and run engine for 2 or 3 minutes at idle. This drives out any air which may still be trapped within

cooling system. STOP ENGINE. Add coolant as necessary until coolant level reaches filler throat of radiator. Reinstall radiator cap.

6. Add coolant to reservoir tank so that its level aligns with Full mark. Then, reinstall cap to reservoir tank aligning match marks on the tank and cap.

CAUTION:  When changing engine coolant, use mixture of 50% water and 50% ethylene-glycol base coolant (AntiFreeze/Anti-corrosion
coolant) for the market where ambient temperature falls lower than -16 °C (3 °F) in winter and mixture of 70% water and 30% ethylene-glycol
base coolant for the market where ambient temperature doesn't fall lower than -16 °C (3 °F).

Even in a market where no freezing temperature is anticipated, mixture of 70% water and 30% ethylneglycol base coolant should be used for the
purpose of corrosion protection and lubrication.

Refer to COOLANT CAPACITY.