suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Emissions - Refuel Vapor Control Valve Damaged/MIL ON|Page 1655 > < Emissions - Refuel Vapor Control Valve Damaged/MIL ON|Page 1653
Page 5
background image

7.

Remove muffler (Figure 8).

WARNING:

To avoid danger of being burned, do not touch the exhaust system when the system is hot. Any service on the exhaust system should be
performed when the system has cooled down.

8.

Disconnect connectors from EVAP canister air valve. Be sure to remove all debris around the quick connectors with compressed air before
disconnecting. To disconnect the quick connectors push both sides of joint in while pulling hose joint out (Figure 9).

9.

Disconnect fuel filler hose and breather hose from filler neck (Figure 10).

10.

Use a hand operated pump to pump fuel out through the fuel tank filler.

WARNING:

Never drain or store fuel into an open container to avoid the possibility of fire or explosion.

CAUTION:

Do not force hose from hand operated pump into or out of fuel tank. Doing so may damage inlet valve.

Emissions - Refuel Vapor Control Valve Damaged/MIL ON|Page 1655 > < Emissions - Refuel Vapor Control Valve Damaged/MIL ON|Page 1653