suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Charging Procedures|Page 2790 > < Charging Procedures|Page 2788
Page 1
background image

Battery: Service and Repair
Dismounting, Handling and Remounting

DISMOUNTING 

1. Disconnect negative cable.
2. Disconnect positive cable.
3. Remove retainer.
4. Remove battery.

HANDLING 
When handling battery, following safety precautions should be followed:

-

Hydrogen gas is produced by battery. A flame or spark near battery may cause the gas to ignite.

-

Battery fluid is highly acidic. Avoid spilling on clothing or other fabric. Any spilled electrolyte should be flushed with large quantity of water and
cleaned immediately.

REMOUNTING 

1. Reverse removal procedure.
2. Torque battery cables to specification.

NOTE:  Check to be sure that ground cable has enough clearance to hood panel by terminal.

Tightening Torque
(a): 8 N.m (0.8 kg-mn, 6.0 lb-ft) 

Charging Procedures|Page 2790 > < Charging Procedures|Page 2788