Inspect commutator for insulator depth. Correct or replace if below limit.

Commutator insulator depth "a"
Standard: 0.4 - 0.6 mm (0.015 - 0.023 in.) 
Limit : 0.2 mm (0.008 in.) 

-

Ground Test
Check commutator and armature core. If there is continuity, armature is grounded and must be replaced.

-

Open Circuit Test
Check for continuity between segments. If there is no continuity at any test point, there is an open circuit and armature must be replaced.