Testing and Inspection of A/C Condenser Fan Control System
Condenser Fan: Testing and Inspection
A/C Condenser Fan Control System
A/C CONDENSER FAN CONTROL SYSTEM
System Inspection
WARNING: Keep hands, tools, and clothing away from A/C condenser fan to help prevent personal injury. This fan is electric and can come
on whether or not the engine is running. The fan can start automatically in response to the ECT sensor with the ignition switch in the "ON"
position.
Check system for operation referring to Flow Table B-9. See: Table B-9 A/C Condenser Fan Control System
If A/C condenser fan fails to operate properly, check relay, A/C condenser fan and electrical circuit.