suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Generator Output Test|Page 2886 > < Alternator|Specifications|Page 2883
Page 1
background image

Alternator: Testing and Inspection
Generator Output Test

Generator Output Test

1. Perform the generator system test. Refer to Generator System Check.
2. Replace the generator if it fails that test. Refer to Generator Removal and Installation. If it passes the test, perform the on-vehicle output check

which follows. 

3. Attach a digital multimeter, an ammeter, and a carbon pile load to the vehicle.
4. With the ignition switch in the OFF position, check and record the battery voltage. 
5. Remove the harness connector from the generator. 
6. Turn the ignition to RUN with the engine not running. Use a digital multimeter to check for voltage in the harness connector "L" terminal. 
7. The reading should be near the specified battery voltage of 12 volts. If the voltage is too low, check the indicator "L" terminal circuits for open

and grounded circuits causing voltage loss. Correct any open wires, terminal connections, etc., as necessary. Refer to Charging System Wiring
Diagram.

8. Attach the generator harness connector. 
9. Run the engine at a moderate idle, and measure the voltage across the battery terminals. The reading should be above that recorded in step 14, but

less than 16 volts. If the reading is over 16 volts or below the previous reading, replace the generator. Refer to Generator Removal and
Installation.

10. Run the engine at a moderate idle, and measure the generator amperage output. 
11. Turn on the carbon pile, and adjust it to obtain the maximum amps while maintaining the battery voltage above 13 volts.
12. If the reading is within 15 amps of the generator's rating noted on the generator, the generator is good. If not, replace the generator. Refer to

Generator Removal and Installation.

13. With the generator operating at the maximum output, measure the voltage between the generator housing and the battery negative terminal. The

voltage drop should be 0.5 volt or less. If the voltage drop is more than 0.5 volt, check the ground path from the generator housing to the negative
battery cable.

14. Check, clean, tighten, and recheck all of the ground connections.

Generator Output Test|Page 2886 > < Alternator|Specifications|Page 2883