Cooling Fan Motor Relay, A/T|Testing and Inspection|Page 2630 > < Cooling Fan Motor Relay, A/T|Testing and Inspection
Page 2
background image

speed cooling fan operation by internally grounding the ECM connector terminal C50. This energizes the low speed cooling fan relay and operates the
main cooling fan and the auxiliary cooling fan at low speed as the cooling fans are connected in a series circuit. The ECM controls the high speed
cooling fan operation by internally grounding the ECM connector terminal C50 and the ECM connector terminal E34 at the same time. This energizes
the low speed cooling fan relay, the high speed cooling fan relay, and the series/parallel cooling fan relay resulting in high speed fan operation as the
cooling fans are now connected in a parallel circuit.

Diagnostic Aids

^

If the owner complained of an overheating problem, it must be determined if the complaint was due to an actual boil over, or the engine coolant
temperature gauge indicated overheating. If the engine is overheating and the cooling fans are on, the cooling system should be checked.

^

If the engine fuse block fuses Ef6 become open (blown) immediately after installation, inspect for a short to ground in the wiring of the appropriate
circuit. If the fuses become open (blown) when the cooling fans are to be turned on by the ECM, suspect a faulty cooling fan motor.

^

The ECM will turn the cooling fans on at low speed when the coolant temperature is 97 °C (207 °F). The ECM will turn the cooling fans off when
the coolant temperature is 94 °C (201 °F).

^

The ECM will turn the cooling fans on at high speed when the coolant temperature is 101 °C (214 °F). The ECM will change the cooling fans
from high speed to low speed when the coolant temperature is 98 °C (208 °F).

^

The ECM will turn the cooling fans on at low speed when the A/C system is ON. The ECM will change the cooling fans from low speed to high
speed when the high side A/C pressure is 1,882 kPa (273 psi) then return to low speed when the high side A/C pressure is 1,448 kPa (210 psi).
When the A/C system is ON, the ECM will change the cooling fans from low to high speed when the coolant temperature reaches 117 °C (244 °F)
then return to low speed when the coolant temperature reaches 114 °C (237 °F).

^

The cooling fan circuit can be checked quickly by disconnecting the ECM connector 2 and grounding the connector terminal C50. This should
create low speed cooling fan operation with the ignition ON. By grounding the ECM connector terminals C50 and E34 and turning the ignition
ON, high speed cooling fan operation should be achieved.

Test Description

Number(s) below refer to the step number(s) on the Diagnostic Table.

1. This step, along with Step 5, checks for the ability of the ECM to operate the cooling fans.
2. This step, along with Step 9, checks for the ability of the ECM to operate the cooling fans in response to A/C pressure readings.
3. After confirming battery voltage and the ECM supplying a ground to the coil side of the cooling fan relay A, by jumpering connector terminals 30

and 87 it will be determined if the relay is at fault or a wiring problem is present.

4. This step checks for the presence of battery voltage to the main cooling fan when the A/C is ON. If battery voltage is present and the cooling fans

are not operating, the problem is in the ground side of the cooling fan circuit.

5. By directly grounding the ECM connector terminals C50 and E34, the main and auxiliary cooling fans should run at high speed.

Cooling Fan Motor Relay, A/T|Testing and Inspection|Page 2630 > < Cooling Fan Motor Relay, A/T|Testing and Inspection